AmsW-MBUS

  • S0, Wireless MBUS and Modbus interfaces for Digital Meters

    The AmsW-MBUS is a client interface module in the Amplex Module System. The module offers a number of different interface options especially for AMR installations like Wireless MBUS, S0, MODBUS, DLMS/COSEM. The module act as MBUS master, and can connect to any wireless MBUS heat-, water-, gas or electricity meter. It can read multiple encrypted (AES128) and un-encrypted meters at the same time.

    Two PT100 3-wire temperature sensors can be directly connected to the module and the module features two digital inputs and two analog inputs for monitoring purposes. The two digital inputs can also be configured as open-collector outputs for control of external equipment, e.g. relays.

    AmsW-MBUS can also be used for establishing two-way communication with RS485 compatible utility meters like DLMS meters or industrial monitoring devices running for example Modbus. The AmsW-MBUS module can easily be connected with up to ten child devices.

    The AmsW-MBUS module collects data from the connected devices and subsequently transfers these data to an AmsCPU/AmsCPU-IO module that acts as a data concentrator and WAN module. The AmsCPU module delivers the data to the central server when required. Direct communication and power supply between the AmsW-MBUS module and the AmsCPU module are handled by an incorporated A-Bus interface, which is based on the industrially proven RS-485 technology.

    • A-Bus two-way communication with A-Bus masters, e.g. AmsCPU, AmsCPU-IO
    • The module is a Wireless MBUS master in accordance with EN13757- 4. It can communicate in the following modes: T-mode, S-mode and C-mode. It can handle up to 32 different AES128 encrypted meter connections. In case of un-encrypted connections, the number is only limited by the collision in the spectrum. Wireless MBUS communication is done on 868 MHz and requires an external antenna
    • According to ANSI TIA/EIA-485-A, half duplex
      The module supports the following protocols: General purpose serial communication, dlms mode C, dlms/COSEM (HDLC), Modbus.
    • The module is automatically discovered by the AmsCPU module. In case a module is disconnected from the AmsCPU module, this is reported to the server application and the module is listed as missing. If the module is reconnected to the AmsCPU module or another AmsCPU module, it will be rediscovered by the system.
    • The real-time clock is automatically synchronized with the AmsCPU module which in turn is synchronized with the Network Time Protocol (NTP).
    • AMS Status LED (green): indicates whether the A-Bus is up and running.
    • The software on the AmsW-MBUS module can be updated remotely from the central server.
    • New software is transferred without interrupting the normal functionality of the AmsW-MBUS module. When the software has been transferred, the integrity of the software is checked and the software is installed.
    • A built-in self-test (BIST) is performed after power-up.
    • Watchdog and brown-out reset ensure that the system is up and running at all times.

    • A-Bus client module
    • For use with Amplex service tools.
    • RS485 A and RS485 B connect to one meter or a collection of meters.
      A = inverting pin and B = non-inverting pin.
      The AmsW-MBUS module can be connected to a maximum of 10 meters.
      The AmsW-MBUS module has an internal termination resistor (120 Ohm)
      between RS485 A and RS485 B.
    • Two inputs for industrial standard PT100 temperature sensors that support
      2-wire or 3-wire compensation.
      Temperature range = -40°C to +150°C
      Accuracy = ± 1°C
    • Two digital active-high inputs: Input/Output 1 and 2.
      Input impedance = 510 Ohm (DC)
      Input voltage low = 0-1 V
      Input voltage high = 3-24 V
      AmsW-MBUS reads 0-1 V as logic 0/off and anything above 3 V as logic 1/on. The inputs are functional up to an input voltage of absolute max 30 V
    • Two open-collector outputs for driving, e.g. relays, optocouplers, etc.: Input/Output 1 and 2.
      Max current sink = 70 mA
      Max voltage = 30 V
      When Input/Output 1 and 2 are used as digital outputs, connect, e.g. to drive external relays: See datasheet for examples. Reverse diodes are internally mounted.
    • Two analog inputs: Input 3 and 4, see datasheet.
      Analog input 0-10 V, 4-20 mA (0-20 mA)
      Impedance = 510 Ohm (DC)
      Accuracy = ± 2% FSD
      Can also be used as digital input:
      Threshold of approximately 1 V
      Max input voltage = 12 V (12 VDC out on pin 1)
    • When using the wireless MBUS, connect an external antenna to the SMA connector on the module. For a selection of approved antennas, please look under Ordering Information at the bottom of the datasheet


Supported Meters


Manufacturer Model Protocol Interface
Larsen & Toubro ER300P Modbus AMS RS485, AMS CPU-IO
Larsen & Toubro Nova Modbus AMS RS485, AMS CPU-IO
Larsen & Toubro Quasar Modbus AMS RS485, AMS CPU-IO
Carlo Gavazzi EM24DIN Modbus AMS RS485, AMS Sense, AMS wMBus, AMS CPU-IO
Carlo Gavazzi EM21 Modbus AMS RS485, AMS Sense, AMS wMBus, AMS CPU-IO
Carlo Gavazzi EM21-72R Modbus AMS RS485, AMS Sense, AMS wMBus, AMS CPU-IO
Carlo Gavazzi EM21-72D Modbus AMS RS485, AMS Sense, AMS wMBus, AMS CPU-IO
Circutor CVM-NET Modbus AMS RS485, AMS CPU-IO
DEIF AGC3 Modbus AMS RS485, AMS CPU-IO
DEIF MIB7000 Modbus AMS RS485, AMS CPU-IO
DEIF MIC2 Modbus AMS RS485, AMS CPU-IO
DEIF AMP380 Modbus (via ext interface) AMS RS485, AMS CPU-IO
ZheLiang Yongtailong Electric DDS-1Y Modbus AMS RS485, AMS CPU-IO
FastForward EnergyCam wMBus AMS wMBus, Squid.Link
FastForward EnergyCam 2.0 wMBus AMS wMBus, Squid.Link
Manufacturer Model Protocol Interface
Various manufacturers Pulse-generating meters S0 pulse AMS CPU-IO, AMS Sense, AMS wMBus
Kamstrup Multical 21 wMBus AMS wMBus, Squid.Link
Kamstrup Multical 61 wMBus AMS wMBus, Squid.Link
Diehl Hydrus wMBus AMS wMBus, Squid.Link
Sensus iPerl wMBus AMS wMBus, Squid.Link
FastForward EnergyCam wMBus AMS wMBus, Squid.Link
FastForward EnergyCam 2.0 wMBus AMS wMBus, Squid.Link
Manufacturer Model Protocol Interface
FastForward EnergyCam wMBus AMS wMBus, Squid.Link
FastForward EnergyCam 2.0 wMBus AMS wMBus, Squid.Link
Manufacturer Model Protocol Interface
Kamstrup Multical 601 wMBus AMS wMBus, Squid.Link
Kamstrup Multical 602 wMBus AMS wMBus, Squid.Link
FastForward EnergyCam wMBus AMS wMBus, Squid.Link
FastForward EnergyCam 2.0 wMBus AMS wMBus, Squid.Link
Manufacturer Model Protocol Interface
* * PT100 AMS Sense, AMS wMBus
FastForward EnergyCam wMBus AMS wMBus, Squid.Link
FastForward EnergyCam 2.0 wMBus AMS wMBus, Squid.Link
Danfoss ECL 210/310 Modbus AMS RS485, AMS CPU-IO
Grundfos Magna 3 Modbus AMS RS485, AMS CPU-IO

More meters can be supported using add-on AMS modules – see full list of supported meters, interfaces and protocols here.