Intelligent Modbus Device Interface
The AmsMODBUS module is a client interface module in the Amplex Module System. It consists of two individually controllable relays. These relays are galvanically isolated and are used for switching minor loads on and o directly and three-phase or larger loads via an intermediate breaker. One of the two relays provides both NO and NC functionality.
The AmsSwitch module can be used for a wide range of purposes that require stable and reliable control.
All modules in the Amplex Module System incorporate an A-Bus interface which is based on the industrially proven RS-485 technology. The A-Bus interface is used for power sup- ply and for direct communication between the modules.
-
- A-Bus two-way communication with A-Bus masters, e.g. AmsCPU, AmsPLC+, AmsService
- The module is automatically discovered by the AmsCPU module. In case
a module is disconnected from the AmsCPU module, this is reported to the server application and the module is listed as missing. If the module is reconnected to the AmsCPU module or another AmsCPU module, it will be rediscovered by the system. - The real-time clock is automatically synchronized with the AmsCPU mod- ule which in turn is synchronized with the Network Time Protocol (NTP).
- AMS Status LED (green): indicates whether the A-Bus is up and running.
- The software on the AmsSwitch module can be updated remotely from the central server.
- New software is transferred without interrupting the normal functional- ity of the AmsSwitch module. When the software has been transferred, the integrity of the software is checked and the software is installed.
- A built-in self-test (BIST) is performed after power-up.
- Watchdog and brown-out reset ensure that the system is up and running at all times.
- A-Bus client module
- 250 V AC/30 V DC (resistive)
- 3 A (resistive)
Manufacturer |
Model |
Protocol |
Interface |
Elster Germany |
AS253 |
DLMS/COSEM |
AMS RS485 |
Elster Germany |
AS1253 |
DLMS/COSEM |
AMS RS485 |
Elster Germany |
AS1440 |
DLMS/COSEM |
AMS RS485 |
Elster US |
A1800 |
DLMS/COSEM |
AMS RS485 |
Actaris |
ACE5000 |
Euridis |
AMS Euridis |
Actaris |
ACE6000 |
DLMS/COSEM |
AMS RS485 |
Actaris |
ACE7000 |
DLMS/COSEM |
AMS RS485 |
Echelon |
83331I |
ANSI C12.18/19 |
AMS RS232 |
Iskraemeco |
MT830 |
IEC62056-21 |
AMS RS232 |
Iskraemeco |
MT831 |
IEC62056-21 |
AMS RS485 |
Kamstrup |
162 |
M-Bus |
AMS M-Bus |
Kamstrup |
162J |
DLMS/Cosem |
AMS RS485 |
Kamstrup |
351B/C |
Kamstrup Meter Protocol, DLMS/COSEM |
Optical, AMS RS485 |
Kamstrup |
382B/C |
Kamstrup Meter Protocol, M-Bus |
Optical, AMS M-Bus |
Kamstrup |
382J |
Kamstrup Meter Protocol, DLMS/COSEM |
Optical, AMS RS485 |
Larsen & Toubro |
ER300P |
Modbus |
AMS RS485, AMS CPU-IO |
Larsen & Toubro |
Nova |
Modbus |
AMS RS485, AMS CPU-IO |
Larsen & Toubro |
Quasar |
Modbus |
AMS RS485, AMS CPU-IO |
Landis+Gyr |
E650 |
DLMS/COSEM |
AMS RS485 |
Landis+Gyr |
E350 |
M-Bus |
AMS M-Bus |
Carlo Gavazzi |
EM24DIN |
Modbus |
AMS RS485, AMS Sense, AMS wMBus, AMS CPU-IO |
Carlo Gavazzi |
EM21 |
Modbus |
AMS RS485, AMS Sense, AMS wMBus, AMS CPU-IO |
Carlo Gavazzi |
EM21-72R |
Modbus |
AMS RS485, AMS Sense, AMS wMBus, AMS CPU-IO |
Carlo Gavazzi |
EM21-72D |
Modbus |
AMS RS485, AMS Sense, AMS wMBus, AMS CPU-IO |
Circutor |
CVM-NET |
Modbus |
AMS RS485, AMS CPU-IO |
DEIF |
AGC3 |
Modbus |
AMS RS485, AMS CPU-IO |
DEIF |
MIB7000 |
Modbus |
AMS RS485, AMS CPU-IO |
DEIF |
MIC2 |
Modbus |
AMS RS485, AMS CPU-IO |
DEIF |
AMP380 |
Modbus (via ext interface) |
AMS RS485, AMS CPU-IO |
ZheLiang Yongtailong Electric |
DDS-1Y |
Modbus |
AMS RS485, AMS CPU-IO |
Echelon |
83332-I (ZWMEM101 – Echelon MEP) |
ZigBee |
Squid.Link |
FastForward |
EnergyCam |
wMBus |
AMS wMBus, Squid.Link |
FastForward |
EnergyCam 2.0 |
wMBus |
AMS wMBus, Squid.Link |
Hager |
EC368 |
M-Bus |
AMS M-Bus |
Manufacturer |
Model |
Protocol |
Interface |
Actaris |
Water Meter |
M-Bus |
AMS M-Bus |
Elster |
Q050 |
Severn Trent |
AMS Severn Trent |
Severn Trent |
SM150E |
Severn Trent |
AMS Severn Trent |
Various manufacturers |
Pulse-generating meters |
S0 pulse |
AMS CPU-IO, AMS Sense, AMS wMBus |
Kamstrup |
Multical 21 |
wMBus |
AMS wMBus, Squid.Link |
Kamstrup |
Multical 61 |
wMBus |
AMS wMBus, Squid.Link |
Diehl |
Hydrus |
wMBus |
AMS wMBus, Squid.Link |
Sensus |
iPerl |
wMBus |
AMS wMBus, Squid.Link |
FastForward |
EnergyCam |
wMBus |
AMS wMBus, Squid.Link |
FastForward |
EnergyCam 2.0 |
wMBus |
AMS wMBus, Squid.Link |
Manufacturer |
Model |
Protocol |
Interface |
FastForward |
EnergyCam |
wMBus |
AMS wMBus, Squid.Link |
FastForward |
EnergyCam 2.0 |
wMBus |
AMS wMBus, Squid.Link |
Manufacturer |
Model |
Protocol |
Interface |
Kamstrup |
Multical 601 |
MBus |
AMS M-Bus |
Kamstrup |
Multical 601 |
wMBus |
AMS wMBus, Squid.Link |
Kamstrup |
Multical 602 |
wMBus |
AMS wMBus, Squid.Link |
Kamstrup |
Multical 1 |
MBus |
AMS M-Bus |
FastForward |
EnergyCam |
wMBus |
AMS wMBus, Squid.Link |
FastForward |
EnergyCam 2.0 |
wMBus |
AMS wMBus, Squid.Link |
Manufacturer |
Model |
Protocol |
Interface |
* |
* |
PT100 |
AMS Sense, AMS wMBus |
FastForward |
EnergyCam |
wMBus |
AMS wMBus, Squid.Link |
FastForward |
EnergyCam 2.0 |
wMBus |
AMS wMBus, Squid.Link |
Develco |
SPLZB-131 |
ZigBee |
Squid.Link |
Develco |
ZigBee Wallplug Meter-Relay HA |
ZigBee |
Squid.Link |
Develco |
ZigBee Wallplug HA SP2 |
ZigBee |
Squid.Link |
Develco |
SMSZB-120 |
ZigBee |
Squid.Link |
Develco |
MOSZB-130 |
ZigBee |
Squid.Link |
Develco |
ZHOT101 – ZigBee Occupancy, Temperature & Light Sensor |
ZigBee |
Squid.Link |
Develco |
ZHMS101 – Magnetic Sensor |
ZigBee |
Squid.Link |
Danfoss |
ECL 210/310 |
Modbus |
AMS RS485, AMS CPU-IO |
Grundfos |
Magna 3 |
Modbus |
AMS RS485, AMS CPU-IO |
More meters can be supported using add-on AMS modules – see full list of supported meters, interfaces and protocols here.