Intelligent solutions for Smart City, IoT, utilities and streetlight professionals

AmsMODBUS

  • Intelligent Modbus Device Interface

    The AmsMODBUS module is a client interface module in the Amplex Module System. It consists of two individually controllable relays. These relays are galvanically isolated and are used for switching minor loads on and o directly and three-phase or larger loads via an intermediate breaker. One of the two relays provides both NO and NC functionality.

    The AmsSwitch module can be used for a wide range of purposes that require stable and reliable control.

    All modules in the Amplex Module System incorporate an A-Bus interface which is based on the industrially proven RS-485 technology. The A-Bus interface is used for power sup- ply and for direct communication between the modules.

    • A-Bus two-way communication with A-Bus masters, e.g. AmsCPU, AmsPLC+, AmsService
    • The module is automatically discovered by the AmsCPU module. In case
      a module is disconnected from the AmsCPU module, this is reported to the server application and the module is listed as missing. If the module is reconnected to the AmsCPU module or another AmsCPU module, it will be rediscovered by the system.
    • The real-time clock is automatically synchronized with the AmsCPU mod- ule which in turn is synchronized with the Network Time Protocol (NTP).
    • AMS Status LED (green): indicates whether the A-Bus is up and running.
    • The software on the AmsSwitch module can be updated remotely from the central server.
    • New software is transferred without interrupting the normal functional- ity of the AmsSwitch module. When the software has been transferred, the integrity of the software is checked and the software is installed.
    • A built-in self-test (BIST) is performed after power-up.
    • Watchdog and brown-out reset ensure that the system is up and running at all times.

    • A-Bus client module
    • 250 V AC/30 V DC (resistive)
    • 3 A (resistive)


Supported Meters


Manufacturer Model Protocol Interface
Elster Germany AS253 DLMS/COSEM AMS RS485
Elster Germany AS1253 DLMS/COSEM AMS RS485
Elster Germany AS1440 DLMS/COSEM AMS RS485
Elster US A1800 DLMS/COSEM AMS RS485
Actaris ACE5000 Euridis AMS Euridis
Actaris ACE6000 DLMS/COSEM AMS RS485
Actaris ACE7000 DLMS/COSEM AMS RS485
Echelon 83331I ANSI C12.18/19 AMS RS232
Iskraemeco MT830 IEC62056-21 AMS RS232
Iskraemeco MT831 IEC62056-21 AMS RS485
Kamstrup 162 M-Bus AMS M-Bus
Kamstrup 162J DLMS/Cosem AMS RS485
Kamstrup 351B/C Kamstrup Meter Protocol, DLMS/COSEM Optical, AMS RS485
Kamstrup 382B/C Kamstrup Meter Protocol, M-Bus Optical, AMS M-Bus
Kamstrup 382J Kamstrup Meter Protocol, DLMS/COSEM Optical, AMS RS485
Larsen & Toubro ER300P Modbus AMS RS485, AMS CPU-IO
Larsen & Toubro Nova Modbus AMS RS485, AMS CPU-IO
Larsen & Toubro Quasar Modbus AMS RS485, AMS CPU-IO
Landis+Gyr E650 DLMS/COSEM AMS RS485
Landis+Gyr E350 M-Bus AMS M-Bus
Carlo Gavazzi EM24DIN Modbus AMS RS485, AMS Sense, AMS wMBus, AMS CPU-IO
Carlo Gavazzi EM21 Modbus AMS RS485, AMS Sense, AMS wMBus, AMS CPU-IO
Carlo Gavazzi EM21-72R Modbus AMS RS485, AMS Sense, AMS wMBus, AMS CPU-IO
Carlo Gavazzi EM21-72D Modbus AMS RS485, AMS Sense, AMS wMBus, AMS CPU-IO
Circutor CVM-NET Modbus AMS RS485, AMS CPU-IO
DEIF AGC3 Modbus AMS RS485, AMS CPU-IO
DEIF MIB7000 Modbus AMS RS485, AMS CPU-IO
DEIF MIC2 Modbus AMS RS485, AMS CPU-IO
DEIF AMP380 Modbus (via ext interface) AMS RS485, AMS CPU-IO
ZheLiang Yongtailong Electric DDS-1Y Modbus AMS RS485, AMS CPU-IO
Echelon 83332-I (ZWMEM101 – Echelon MEP) ZigBee Squid.Link
FastForward EnergyCam wMBus AMS wMBus, Squid.Link
FastForward EnergyCam 2.0 wMBus AMS wMBus, Squid.Link
Hager EC368 M-Bus AMS M-Bus
Manufacturer Model Protocol Interface
Actaris Water Meter M-Bus AMS M-Bus
Elster Q050 Severn Trent AMS Severn Trent
Severn Trent SM150E Severn Trent AMS Severn Trent
Various manufacturers Pulse-generating meters S0 pulse AMS CPU-IO, AMS Sense, AMS wMBus
Kamstrup Multical 21 wMBus AMS wMBus, Squid.Link
Kamstrup Multical 61 wMBus AMS wMBus, Squid.Link
Diehl Hydrus wMBus AMS wMBus, Squid.Link
Sensus iPerl wMBus AMS wMBus, Squid.Link
FastForward EnergyCam wMBus AMS wMBus, Squid.Link
FastForward EnergyCam 2.0 wMBus AMS wMBus, Squid.Link
Manufacturer Model Protocol Interface
FastForward EnergyCam wMBus AMS wMBus, Squid.Link
FastForward EnergyCam 2.0 wMBus AMS wMBus, Squid.Link
Manufacturer Model Protocol Interface
Kamstrup Multical 601 MBus AMS M-Bus
Kamstrup Multical 601 wMBus AMS wMBus, Squid.Link
Kamstrup Multical 602 wMBus AMS wMBus, Squid.Link
Kamstrup Multical 1 MBus AMS M-Bus
FastForward EnergyCam wMBus AMS wMBus, Squid.Link
FastForward EnergyCam 2.0 wMBus AMS wMBus, Squid.Link
Manufacturer Model Protocol Interface
* * PT100 AMS Sense, AMS wMBus
FastForward EnergyCam wMBus AMS wMBus, Squid.Link
FastForward EnergyCam 2.0 wMBus AMS wMBus, Squid.Link
Develco SPLZB-131 ZigBee Squid.Link
Develco ZigBee Wallplug Meter-Relay HA ZigBee Squid.Link
Develco ZigBee Wallplug HA SP2 ZigBee Squid.Link
Develco SMSZB-120 ZigBee Squid.Link
Develco MOSZB-130 ZigBee Squid.Link
Develco ZHOT101 – ZigBee Occupancy, Temperature & Light Sensor ZigBee Squid.Link
Develco ZHMS101 – Magnetic Sensor ZigBee Squid.Link
Danfoss ECL 210/310 Modbus AMS RS485, AMS CPU-IO
Grundfos Magna 3 Modbus AMS RS485, AMS CPU-IO

More meters can be supported using add-on AMS modules – see full list of supported meters, interfaces and protocols here.